man in blue with helmet

AERZEN Turbo in new splendour.

Series TB for small and medium volume flows is upgraded.

05/02/2016

Since the energy requirement for the aeration of aeration tanks in wastewater treatment plant reaches 70 % , energy efficiency is still the decisive indicator for a healthy energy balance. Many AERZEN customers worldwide could already benefit from the energy savings since 2010 when the product with the extremely efficient turbo technology was launched. The successful series TB has now been revised.

The AERZEN turbo series TB was particularly developed for biologically operating wastewater treatment plants with small and medium volume flow requirements. AERZEN sells the packaged units in 11 series which offer air volumes from 300 to 6,000 m³/h for pressure ranges from 300 to 1,000 mbar. The innovative system experienced a number of constructive adjustments resulting in another positive effect on the energy saving. Depending on the volume flow and the pressure range, the energy requirement can be reduced by another 6 %.

The TB series is the most compact type of construction in the lower volume flow range worldwide. The small footprint leads to an extremely high power density in relation to the size and conveying volume. Constructive improvements within the packaged unit ensure an optimised air guidance which, eventually, minimizes pressure losses at the intake side. Since electrical and mechanical engineering are separated by open ground, heat losses of the power electronics are not passed to the process air. The separation increases the efficiency and the reliability of the electrical engineering. Thus, susceptibility of the electrical components can already be avoided in the preliminary stages.

Further positive characteristics of the compact system are the integrated silencer for the cooling air outlet and the blow-off valve. The plug&play system operates almost maintenance-free and absolutely oil-free; only filters have to be changed in regular cycles. The air flow is not measured indirectly, as it is the conventional way, i. e. derived from the power consumption. It is performed according to the Venturi principle. By means of a differential pressure measurement the real air-mass flow is measured in the inlet cone of the stage. In this way, the packaged unit provides real measured values for the monitoring and the internal safety devices, as for example for the AERZEN Feature-High-Rise-to-Surge. The extremely fast response characteristic of the frequency converter enables it to compensate difficult conditions, as for example to react on pressure fluctuations by fast change of speed. The result is a significant minor sensibility of the turbo blower throughout the total control range. Thus, users can comprehend at any time the exact quantity that is really led into their tanks. This parameter is also shown directly via the control system.


more releases

- Blower and compressor technology installed in slim ISO container

Blower technology in containers has the potential to make process air supply noticeably leaner, more flexible and easier. AERZEN has already gained many years of experience in this field from its own rental business and is now using this know-how for a new solution. The idea: compressed air from the...

läs mer

- The new AERsmart: also for varying pressure.

AERsmart: the name stands for a composite control system that has set out to effectively improve the energy efficiency of oxygen supply in aeration tanks, especially in wastewater technology. AERZEN has now further developed the solution. The control system for the composite operation of different...

läs mer

- AERZEN expands its general turbo program. Highest energy efficiency with smallest footprint.

The Aerzen Turbo G5plus series is one of the most compact and efficient turbos in its class. The new AT 60 size brings with it numerous innovations. In addition to increased system pressure, the new turbo also scores with an extended control range and an efficiency increase of up to 10%.

läs mer